Air Conditioning Clinic Cooling and Heating Load Estimation by The Trane Company

By The Trane Company

Completely new, haven't used but

Show description

Read Online or Download Air Conditioning Clinic Cooling and Heating Load Estimation One of the Fundamental Series TRG-TRC002-EN PDF

Best clinical medicine books

Research Methods in Clinical Psychology An Introduction for Students and Practitioners,2nd Ed

Study equipment IN scientific PSYCHOLOGY is a reader-friendly creation to doing, and wondering, study for medical psychologists. This systematic advisor takes scholars and practitioners during the simple steps of a examine venture, from begin to end. it really is a useful software if you happen to are looking to behavior their very own study, or just desire a larger figuring out of released examine.

Genomics, Proteomics, and Clinical Bacteriology: Methods and Reviews

It's crucial that every one medical bacteriologists develop into energetic members within the present genomics and proteomics revolution if the numerous achievements of genome sequencing and research are to provide genuine merits for sufferer care. In Genomics, Proteomics, and scientific Bacteriology, a panel of the world over well known specialists studies how genomics has supplied novel tools for bacterial research and complex our wisdom of bacterial pathogenicity.

Clinicians Guide to Chronic Headache and Facial Pain

As headache and facial discomfort are of the most typical clinical court cases, it really is crucial that clinicians are good built to deal with those matters. Clinician’s consultant to power Headache and Facial ache is designed for all clinicians facing those syndromes in day-by-day practice—whether within the outpatient, emergency, or ambulatory environment.

Clinical Cardiac Pacing, Defibrillation and Resynchronization Therapy, Third Edition

This third variation provides state of the art criteria of pacing and defibrillation to maintain you on the vanguard of this swiftly increasing box. you will discover assurance of all of the new units and administration suggestions you want to clear up an entire variety of scientific difficulties utilizing modern day most sensible techniques. Written by means of global gurus on pacing and units for cardiac care, this new full-color third variation is the more effective than ever!

Extra info for Air Conditioning Clinic Cooling and Heating Load Estimation One of the Fundamental Series TRG-TRC002-EN

Sample text

The data in Figure 49 are an excerpt from this standard. 01 m3/s] of outdoor air required per person in an office space. 18 × (15 – 10) = 2,709 W] 46 TRG-TRC002-EN period two Cooling Load Estimation notes DLU KDQGOHU IDQ PRWRU Figure 51 System Heat Gains There may be others sources of heat gain within the HVAC system. One example is the heat generated by fans. When the supply fan, driven by an electric motor, is located in the conditioned airstream, it adds heat to the air. Heat gain from a fan is associated with three energy conversion losses.

4 × 7 = 359 W] Table 5. CLTDs for Glass, °F Hour 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 0 -1 -2 -2 -2 -2 0 2 4 7 9 12 13 14 14 13 12 10 8 6 4 3 2 Table 6. CLTDs for Glass, °C Hour 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 0 -1 -1 -1 -1 -1 0 1 2 4 5 7 7 8 8 7 7 6 4 3 2 2 1 Source: 1997 ASHRAE Handbook—Fundamentals, Chapter 28, Table 34 VXQ UD\V UHIOHFWHG HQHUJ\ WUDQVPLWWHG HQHUJ\ JODVV ZLQGRZ Figure 29 Solar Radiation through Glass Previously, we estimated the heat transferred through glass windows by the process of conduction.

7ºC] Using the psychrometric chart, the condition of this air mixture (C) must fall on a line connecting the condition of the recirculated air (A) and the condition of the outdoor air (B). 2°C]. Because the recirculated air constitutes a larger percentage (88%) of the mixture, the mixed-air condition (C) is much closer to the recirculated air condition (A) than the outdoor design condition (B). TRG-TRC002-EN 57 period three Psychrometric Analysis notes $ $ '  % %    6+5  VHQVLEOH KHDW UDWLR H WXU HUD S WHP OE X E W & & ZH ƒ) >ƒ&@ GU\ GU\EXOE WHPSHUDWXUH Figure 64 The next step is to determine the supply-air condition (dry-bulb and wet-bulb temperatures) necessary to absorb the sensible and latent heat in the space.

Download PDF sample

Air Conditioning Clinic Cooling and Heating Load Estimation by The Trane Company
Rated 4.67 of 5 – based on 37 votes